TUV-CE QUICK CONNECT
TRANSFORMERS FILE
# E86403 & E178395
PASSED EN61558 FILE
# LR80864
UL60601-1
and CSA-C22.2 601.1-M90 certified construction.
Meets
UL1097 double insulation requirements
SERIES
4-49 *NEW
400VA MODEL*
4,000-Volt
RMS Hipot. In a variety of sizes. Maximum operating temperature 155°C.
Available with either 115V or
dual 115/230V primary. MCI's split bobbin and non-concentric winding provide
better insulation and high signal
isolation, thus eliminating the need for electrostatic shielding.
These transformers are designed to pass VDE's strict creepage distance
requirements. Adaptations of standard transformers are also available.
Dots on schematics shown below indicate like polarity.

CURRENT
RATINGS (AMPS RMS)
| Last 3 Digits of Part Number: |
-010 |
-012 |
-016 |
-020 |
-024 |
-028 |
-036 |
-048 |
-56 |
-120 |
-230 |
| First
4 Digits: |
SERIES CONNECTION
|
|
|
|
SECONDARY VOLTAGE
|
| 10V CT |
12.6V CT |
16V CT |
20V CT |
24V CT |
28V CT |
36V CT |
48V CT |
56V CT |
120V CT |
230V CT |
| 4-49-4__ |
2.50 |
2.00 |
1.60 |
1.25 |
1.00 |
.90 |
.70 |
.50 |
.45 |
.20 |
.11 |
| 4-49-5__ |
4.30 |
3.40 |
2.70 |
2.20 |
1.80 |
1.50 |
1.20 |
.90 |
.75 |
.35 |
.19 |
| 4-49-6__ |
8.00 |
6.30 |
5.00 |
4.00 |
3.30 |
2.80 |
2.20 |
1.65 |
1.40 |
.65 |
.35 |
| 4-49-7__ |
13.00 |
10.30 |
8.10 |
6.50 |
5.40 |
4.60 |
3.60 |
2.70 |
2.30 |
1.10 |
.57 |
| 4-49-8__ |
17.50 |
14.00 |
11.00 |
8.80 |
7.30 |
6.25 |
4.80 |
3.65 |
3.10 |
1.45 |
.76 |
| 4-49-9__ |
20.00 |
15.00 |
12.50 |
10.00 |
8.00 |
7.00 |
5.50 |
4.00 |
3.50 |
1.60 |
.85 |
| 4-49-0__ |
25.00 |
20.00 |
15.50 |
12.00 |
10.00 |
8.90 |
6.90 |
5.20 |
4.46 |
2.00 |
1.0 |
| *4-49-1__
|
N/A |
N/A |
N/A |
N/A |
16.60 |
14.30 |
11.10 |
8.30 |
7.15 |
3.30 |
1.75 |
|
PARALLEL CONNECTION |
|
|
|
SECONDARY VOLTAGE |
| 5V |
6.3V |
8V |
10V |
12V |
14V |
18V |
24V |
28V |
60V |
115V |
| 4-49-4__ |
5.00 |
4.00 |
3.20 |
2.50 |
2.00 |
1.86 |
1.40 |
1.00 |
.90 |
.40 |
.22 |
| 4-49-5__ |
8.60 |
6.80 |
5.40 |
4.40 |
3.60 |
3.00 |
2.40 |
1.80 |
1.50 |
.70 |
.38 |
| 4-49-6__ |
16.00 |
12.60 |
10.00 |
8.00 |
6.60 |
5.60 |
4.40 |
3.30 |
2.80 |
1.30 |
.70 |
| 4-49-7__ |
26.00 |
20.60 |
16.20 |
13.00 |
10.80 |
9.20 |
7.20 |
5.40 |
4.60 |
2.10 |
1.14 |
| 4-49-8__ |
35.00 |
28.00 |
22.00 |
17.60 |
14.60 |
12.50 |
9.60 |
7.20 |
6.20 |
2.80 |
1.52 |
| 4-49-9__ |
40.00 |
31.00 |
25.00 |
20.00 |
16.60 |
14.00 |
11.00 |
8.00 |
7.00 |
3.30 |
1.70 |
| 4-49-0__ |
50.00 |
40.00 |
31.00 |
25.00 |
20.00 |
17.80 |
13.80 |
10.00 |
8.90 |
4.00 |
2.00 |
| *4-49-1__
|
N/A |
N/A |
N/A |
N/A |
33.30 |
28.60 |
22.20 |
16.60 |
14.30 |
6.60 |
3.50 |
*Certified
by TUV to EN61558 and UL /CSA standards by Underwriters labs. File# E86403.
& TUV , UL60601-1 and CSA-C22.2
601.1-M90 certifications pending.
| DIMENSIONS
|
| Transformer
|
VA |
Schematic
|
Mounting Style
|
L |
W |
H |
A |
B |
C |
Terminals |
ML |
MW |
Screw
Size |
Maximum
Number Terminals |
Lbs. |
|
4-49-4__
|
25
|
1
|
C
|
2-13/16
|
1-7/8
|
2-5/16
|
2
|
1-1/8
|
5/16
|
3/16
|
2-3/8
|
|
6
|
10
|
1.25
|
|
4-49-5__
|
43
|
1
|
C
|
3-1/8
|
2-1/16
|
2-11/16
|
2-1/4
|
1-1/8
|
3/16
|
13/16
|
2-13/16
|
|
6
|
10
|
1.60
|
|
4-49-6__
|
80
|
2
|
D
|
2-1/2
|
2-3/8
|
3
|
|
1-3/8
|
5/16
|
3/16
|
2
|
2-3/16
|
6
|
12
|
2.80
|
|
4-49-7__
|
130
|
2
|
D
|
2-13/16
|
2-7/8
|
3-3/8
|
|
1-5/8
|
3/8
|
1/4
|
2-1/4
|
2-1/2
|
8
|
12
|
4.10
|
|
4-49-8__
|
175
|
2
|
D
|
3-1/8
|
2-7/8
|
3-3/4
|
|
1-5/8
|
3/8
|
1/4
|
2-1/2
|
2-1/2
|
8
|
12
|
5.50
|
|
4-49-9__
|
200
|
3
|
D
|
3-1/8
|
3-3/8
|
3-3/4
|
|
1-7/8
|
3/8
|
1/4
|
2-1/2
|
2-3/4
|
8
|
28
|
6.10
|
|
4-49-0__
|
250
|
3
|
D
|
3-1/8
|
3-7/8
|
3-3/4
|
|
2-5/16
|
3/8
|
1/4
|
2-1/2
|
3-3/16
|
8
|
28
|
7.00
|
|
*4-49-1__
|
400
|
3
|
D
|
3-7/16
|
4-1/4
|
4-1/8
|
|
2-9/10
|
3/8
|
1/4
|
2-3/4
|
3-11/16
|
8
|
28
|
10.7
|
*Certified
by TUV to EN61558 and UL /CSA standards by Underwriters labs. File#
E86403., UL60601-1 and CSA-C22.2 601.1-M90
certifications pending.
To determine part number for specific transformer to be ordered:
1.
Locate the column, in the table, for the required voltage.
2.
In the voltage column, locate the required current rating.
3.
Moving left from the current rating, find the number indicating required
primary-dual 115/230V.
4.
Derive part number by combining digits identifying required primary
and digits at top of column giving required voltage.
Back
to Index
Horizontal
P.C. Transformers | Vertical
P.C. Transformers | Low
Profile P.C. Transformers New
Larger Low Profile Transformer |
Quick
Connect Power Transformers |
Horizontal
P.C. Encapsulated Transformers
| VDE
Horizontal P.C. Transformers |
VDE
Quick Connect Power Transformers |
VDE
P.C. Mount Transformers |
VDE
Quick Connect Transformers |
International
Style Transformers | Toroids
| Low
Profile Switchmode Transformers
| Low
Profile Switchmode Transformers
|
|