UL CLASS 2 & TUV-CE CERTIFIED
P.C. MOUNT TRANSFORMERS
UL60601-1
and CSA-C22.2 601.1-M90 certified construction.
Meets
UL1097 double insulation requirements
|
SERIES
4-24

FILE
# E120827 &
E178395
PASSED EN61558
UL
files here
|
!NOW
AVAILABLE WTIH!
LEAD WIRES
SINGLE 115V
OR
230V
PRIMARY
OR
DUAL 115/230 PRIMARIES
4,000-Volt
RMS Hipot, in a variety of sizes. Maximum operating temperature
155°C. Available with 115/230V primary. MCI's split bobbin and
non-concentric winding provide better insulation and high signal
isolation, thus eliminating the need for electrostatic shielding.
These transformers are designed to pass CE's strict creepage
distance requirements. Adaptations of standard transformers
are also available. Dots on schematics shown below indicate
like polarity.
|

 
|
To determine part number
for specific transformer to be ordered:
- Locate the column, in the table, for the required VA size..
- In the voltage column, locate the required voltage rating..
- Locate the Model number in the column to the left of the
voltage.
- Locate the fuse required in the fuse column.
- *Non-Inherently limited maximum allowed fuse specified.
All primaries are 115/230 volts 50/60Hz
|
 |
Most
models also available channel mount and lead wires
|
VA
SIZE
|
MODEL
NUMBER
|
VOLTAGE
|
CURRENT
|
FUSE
|
|
2.5
VA
|
4-24-3__
|
|
|
|
|
4-24-3010
|
10
|
.25A
|
Not Required
|
|
4-24-3012
|
12
|
.20A
|
Not Required
|
|
4-24-3016
|
16
|
.15A
|
Not Required
|
|
4-24-3020
|
20
|
.12A
|
Not Required
|
|
4-24-3024
|
24
|
.10A
|
Not Required
|
|
|
4-24-4__
|
|
|
|
|
5VA
|
4-24-4010
|
10
|
.50A
|
Not Required
|
|
4-24-4012
|
12
|
.40A
|
Not Required
|
|
4-24-4016
|
16
|
.31A
|
Not Required
|
|
4-24-4020
|
20
|
.25A
|
Not Required
|
|
4-24-4024
|
24
|
.21A
|
Not Required
|
|
|
4-24-5__
|
|
|
|
|
10
VA
|
4-24-5010
|
10
|
1.A
|
Not Required
|
|
4-24-5012
|
12
|
.80A
|
Not Required
|
|
4-24-5016
|
16
|
.62A
|
Not Required
|
|
4-24-5020
|
20
|
.50A
|
Not Required
|
|
4-24-5024
|
24
|
.42A
|
Not Required
|
|
|
4-24-6__
|
|
|
|
|
|
4-24-6010
|
10
|
2A
|
Not Required
|
|
4-24-6012
|
12
|
1.6A
|
Not Required
|
|
4-24-6016
|
16
|
1.25A
|
Not Required
|
|
4-24-6020
|
20
|
1.0A
|
Not Required
|
|
4-24-6024
|
24
|
.83A
|
Not Required
|
|
|
4-24-7__
|
|
|
|
|
30VA
|
4-24-7012
|
12
|
2.4A
|
3A FUSE*
|
|
4-24-7016
|
16
|
1.9A
|
Not Required
|
|
4-24-7020
|
20
|
1.5A
|
Not Required
|
|
4-24-7024
|
24
|
1.25A
|
Not Required
|
|
|
4-24-8__
|
|
|
|
|
56VA
|
4-24-8012
|
12
|
4.66.A
|
5A FUSE*
|
|
4-24-8024
|
24
|
2.33A
|
2.5AFUSE*
|
|
DIMENSIONS
|
| Transformer
|
VA |
Schematic |
Mounting
Style
|
L
|
W
|
H
|
A
|
B
|
C
|
Pin
Dimensions
|
MW
|
ML
|
Screw
Size
|
Maximum
Number
Terminals
|
Lbs.
|
| 4-24-3__ |
2.5 |
1 |
A |
1-5/8 |
1-7/16 |
1-1/8 |
.200 |
.250 |
1.000 |
.025 sq. |
1-1/16 |
|
4 |
8 |
.25 |
| 4-24-4__ |
5.0 |
1 |
A |
1-5/8 |
1-7/16 |
1-3/8 |
.200 |
.400 |
1.000 |
.025 sq. |
1-1/16 |
|
4 |
8 |
.37 |
| 4-24-5__ |
10.0 |
1 |
A |
1-7/8 |
1-9/16 |
1-3/8 |
.200 |
.400 |
1.140 |
.036 sq. |
1-1/4 |
|
4 |
8 |
.53 |
| 4-24-6__ |
20.0 |
2 |
A |
2-1/4 |
1-7/8 |
1-5/8 |
.400 |
.400 |
1.460 |
.036 sq. |
1-1/2 |
|
4 |
12 |
.90 |
| 4-24-7__ |
30.0 |
2 |
B |
2-5/8 |
2-3/16 |
1-9/16 |
.275 |
|
1.680 |
.045 sq. |
1-3/4 |
2-3/16 |
6 |
12 |
1.15 |
| 4-24-8__ |
56.0 |
2 |
B |
3 |
2-1/2 |
1-13/16 |
.300 |
|
1.900 |
.045 sq. |
2. |
2-1/2 |
6 |
12 |
1.70 |
MCI
TRANSFORMER CORPORATION
411 Manhattan Avenue, Babylon, NY 11704 631. 587. 0510
FAX: 631. 587. 0624
25 Blodgett Street, Orange, MA 01364 978. 544. 8272
FAX: 978. 544. 8356
150 Sanhedrin, Willits, CA 95490 707. 459. 5994 FAX:
707. 459. 5998
Email us your questions at info@mcitransformer.com
|