QUICK CONNECT TRIPLE OUTPUT TRANSFORMERS

SERIES 4-06-X5 & 4-07-X5

FILE# E86403


MCI has added these transformers to our product line for our customers with a need for one transformer to supply either 5VDC and ±12VDC or 5VDC and ±15VDC, in 3 power ratings of 35, 22.4, and 13.8 watts DC regulated. There are 2 primary voltages available. Our 4-06 series which is for 100-130 volts, and our 4-07 series which is for either 100-130 volts or 200-260 volts. The additional components necessary are supplied in the chart below.
                          

DIMENSIONS
Size Regulated Power Watts L W H A B ML Lbs
6 13.8 3-1/4 1-3/4 1-15/16 2-15/16 1-1/16 2-13/16 1.1
7 22.4 3-11/16 1-13/16 2-1/4 2-11/16 1-1/16 3-1/8 1.7
8 35.0 4-1/32 2-1/4 2-9/16 3-1/16 1-5/16 3-9/16 2.75


SPECIFICATION
MCI
Part NO.
PRIMARY 50/60 Hz
DC OUTPUT SIZE Regulated
Power
115V 115/230V OUTPUT 1 OUTPUT 2 WATTS
4-06-6512 4-07-6512 5V @ 1.75A ±12V @ 210MA 6 13.8
4-06-6515 4-07-6515 ±15V @ 350MA
4-06-7512 4-07-7512 5V @ 2.8A ±12V @ 175MA 7 22.4
4-06-7515 4-07-7515 ±15V @ 280MA
4-06-8512 4-07-8515 5V @ 4A ±12V @ 600MA 8 35.0
4-06-8515 4-07-7515 ±15V @ 500MA
MCI
PART NO.
PRIMARY 50/60 Hz
Suggested Components
C2, C4, See Note *
115V 115/230V D1 µ C1 IC1 ¥ D2 µ C3 IC2 ¥ IC3 ¥
4-06-6512 4-07-6512 3N253 10 KMFD @ 20VDC LM 323K-5 3N247 1.5 KMFD @ LM 340K-15 LM 340K-12 LM 320K-15
4-06-6515 4-07-6515 LM 340K-15 LM 320K-15
4-06-7512 4-07-7512 MDA-400 15 KMFD @ 20VDC LM 323K-5 3N247 2 KMFD @ 50VDC LM 340K-12 LM 320K-12
4-06-7515 4-07-7515 LM 340K-15 LM 320K-15
4-06-8512 4-07-8512 MDA-800 26 KMFD @ 20VDC LM 338 ** 3N247 3.1 KMFD@ 50VDC LM 340K-12 LM 320K-12
4-06-8515 4-06-8515 LM 340K-15 LM 320K-15
*: Output capacitors C2 and C4 are required to stabilize regulators. Values can be 1 MFD min. tantalum or 10 MFD min. electorlytic, 20V min.
**: LM-338 is an adjustable regulator and MFR's speicfications (National Semiconductor) should be consulted for values of external components.
¥: All IC's are National Semiconductor types.
µ: All diodes are Motorola types.


To determine part number for specific transformer to be ordered:

  1. Locate the column, in the table, for the required voltage.
  2. In the voltage column, located the required current rating.
  3. Moving left from the current rating, find the number indicating required primary-single 115V primary or dual 115/230V.
  4. Derive part number by combining digits identifying required primary and digits at top of column giving required voltage.

    Back to Index

    Horizontal P.C. Transformers | Vertical P.C. Transformers | Low Profile P.C. Transformers New Larger Low Profile Transformer | Quick Connect Power Transformers | Horizontal P.C. Encapsulated Transformers | VDE Horizontal P.C. Transformers | VDE Quick Connect Power Transformers | VDE P.C. Mount Transformers | VDE Quick Connect Transformers | International Style Transformers | Toroids | Low Profile Switchmode Transformers | Low Profile Switchmode Transformers |


    MCI TRANSFORMER CORPORATION
    411 Manhattan Avenue, Babylon, NY 11704 •
    631. 587. 0510 • FAX: 631. 587. 0624
    25 Blodgett Street, Orange, MA 01364 • 978. 544. 8272 • FAX: 978. 544. 8356
    150 Sanhedrin, Willits, CA 95490 • 707. 459. 5994 • FAX: 707. 459. 5998

    Email us your questions at info@mcitransformer.com